3.2.4.2

Optimised path positioning with arbitrary rotation of the encoder


If more than one rotation of the encoder is required for the entire travel path, the overflow point

5

must be

determined. This results from half of the entire travel path. This value must be entered in parameter P615
"Maximum Position". Here it should be noted that the precision of the value may have a maximum of three
decimal places. A deviant error causes an additional error with each overflow.

NOTE

If an addition of the errors is to be avoided, the system must be referenced again after each
rotation.

-37.875

37.875

-12.625

12.625

0

50.5 / -50.5

-25.25

25.25

-37.875

37.875

-12.625

12.625

0

50.5 / -50.5

-25.25

25.25

a) normal travel path

b) optimised travel path

Example:

The total travel path is 101 rotations of the encoder, then the "Maximum Position" in P615 = 0.5 * 101

rotations. = 50.5 rotations must be entered.


The above example is for a speed ratio or reduction ratio of "1". The maximum value of the position or the
overflow point is calculated as follows:

n

max

:

Maximum value of motor rotation

n

max

= 0.5 * U

D

* Ü

b

/ U

n

Ü

b

:

Speed ratio (P607[01])

U

n

:

Reduction ratio (P608[01])

U

D

Rotations of rotary encoder

Example:

The incremental encoder is installed on the output side of the gear unit. The gear unit has a ratio
of i = 26.3.

n

max

=0.5 * 101 rotations * 263 / 10 = 1328.15 rotations.