NORD Drivesystems BU0210 User Manual

Page 50

Advertising
background image

SK 2x5E with "PosiCon Functionality"

50

Subject to technical amendments

BU 0210 GB

Display in the
ControlBox

Fault

text in the ParameterBox

Cause

Remedy

E013 / E14.5

Pos. diff. <> Speed

Change of position and speed do not match

 Check the position detection and the control

setting in P630

E013 / E14.6

Diff. between Abs. and Inc.

Difference between absolute and incremental
encoders

 Check the position detection and the control

setting in P631

 Position change for the absolute and incremental

encoders do not match

E013 / E14.7

Max. Pos. Exceeded

Maximum position exceeded

 Check the specified setpoint and the control

setting in P615

E013 / E14.8

Mon. Pos. Undershot

Minimum position undershot

 Check the specified setpoint and the control

setting in P616

7.2 Troubleshooting table


The following table contains the most frequent sources of faults and the associated symptoms. It is
recommended that the same sequence as for commissioning is used for troubleshooting. I.e. first check if the
axis runs without control and then test the speed and position controls.


7.2.1

Sources of faults in servo mode operation (without position control)

Symptom

Additional test

Possible cause

Motor only runs slowly,
motor vibrates

Change sign in P301

 incorrect assignment of motor direction

to the incremental encoder direction

 Incorrect incremental encoder type
 Encoder

cable

interrupted

 Encoder voltage supply missing
 Incorrect pulse number parameterised
 Incorrect motor parameters
 Encoder track missing

Motor rotates correctly, but
vibrates at low speeds
Switch-off of overcurrent at
higher speeds

Problem disappears when the
servo mode is switched off

 Incremental encoder incorrectly

mounted

 Interference in encoder signals

Overcurrent switch-off when
braking

Motor in field weakening
operation

 For field weakening operation in servo

mode, the torque limit must not exceed
200%

Advertising