NORD Drivesystems BU0210 User Manual

Page 41

Advertising
background image

4 Parameter settings


BU 0210 GB

Subject to technical amendments

41

Parameters
[factory setting]

Setting value / Description / Note

Device

Supervisor

Parameter
set

P626

Comparative Position Output

S

-50000...50000,000 rev

[ 0 ]

Comparative position for the settings 22, 23 and 25, 26 of relays 1 and 2 or
outputs DOUT 1 and DOUT 2, as well as for the Bus IO Out Bits.

NOTE:

For further information please refer to Sections 3.8.1 and 3.8.2

P630

Position slip error

S

0.00...99.99 rev

[ 0 ]

The permissible deviation between the estimated and the actual position can
be adjusted. As soon as a target position is reached, the estimated position is
set to the current actual position.

If a value which is too low is selected, the error message "E14.5" "position
change and number of rotations do not match" can occur for the slip position
monitoring.

With a setting of "0" the slip error monitoring is disabled.

P631

Abs/Inc slip error

S

0.00...99.99 rev

[ 0 ]

The permissible deviation /slip error between the absolute encoder and the
incremental encoder can be adjusted.

If a value which is too low is selected, the error message "E14.6" position
change for absolute and incremental encoder does not match" can occur for
the slip error monitoring.

With a setting of "0" the slip error monitoring is disabled.

P640

Unit of pos. value

S

0 ... 9

[ 0 ]

Setting the measurement units:

1 =

Rev

(Rotations)

2 =

°

(Degrees)

3 =

rad

(Radians)

4 =

mm

(Millimetres)

5 =

cm

(Centimetres)

6 =

dm

(Decimetres)

7 =

m

(Metres)

8 =

in

(Inch)

9 =

ft

(Feet)

10 =

(no

unit)

NOTE:

For further information please refer to Section 3.5

Advertising