Parameter

Setting / Description / Note

Available with option

P600 (P)

Position control ON / OFF

POS

0...2

[ 0 ]

Activation of position control

0:

OFF

1:

Mode 1 ON (constant progression at maximum frequency)

2:

Mode 2 ON (constant progression at setpoint frequency)

P601

Current actual position value

POS

-50000...50000.000 rev.

The current actual position value will be displayed.

P602

Current setpoint position value

POS

-50000...50000.000 rev.

The current setpoint position value will be displayed.

P603

Current position variance

POS

-50000...50000.000 rev.

The current deviation between actual and setpoint position will be displayed.

P604

Displacement measurement system

POS

0...1

[ 1 ]

Way the actual position value is ascertained, in other words type of the shaft encoder being
used

0:

Incremental value shaft encoder

1:

Absolute value shaft encoder

P605

Absolute value encoder

POS

0...15

[ 15 ]

The type of the absolute value shaft encoder is set here.

0:

SSI single-turn 512 increments

1: SSI single-turn 1024 increments
2:

SSI single-turn 2048 increments

3:

SSI single-turn 4096 increments

4:

SSI 16-revolution multi-turn 512 increments

5:

SSI 16-revolution multi-turn 1024 increments

6:

SSI 16-revolution multi-turn 2048 increments

7:

SSI 16-revolution multi-turn 4096 increments

8:

SSI 256-revolution multi-turn 512 increments

9:

SSI 256-revolution multi-turn 1024 increments

10:

SSI 256-revolution multi-turn 2048 increments

11:

SSI 256-revolution multi-turn 4096 increments

12:

SSI 4096-revolution multi-turn 512 increments

13:

SSI 4096-revolution multi-turn 1024 increments

14:

SSI 4096-revolution multi-turn 2048 increments

15:

SSI 4096-revolution multi-turn 4096 increments