NORD Drivesystems BU0710 User Manual

Page 29

Advertising
background image

6 Fault clearance

BU 0710 GB

29

3. Typical error sources in position control with incremental position recognition (without absolute

encoder)

Symptom

Additional checking

Possible cause

Reference point error

• Reference point tracking

completed but failed

• Encoder lacks zero track, or

encoder is defective

Drive drifts away from desired
position

• Encoder cable affected by

interference pulses

Fault occurs even at low speed
(n < 1000 1/min))

• Encoder cable affected by

interference pulses

No repetitive accuracy when
moving into identical positions
several times

Fault occurs at high speed only
(n > 1000 1/min)

• Number of graduation marks

too high considering the length
of encoder cable / the cable
type (pulse frequency too high)

4. Typical error sources in position control with absolute encoder

Symptom

Additional checking

Possible causes

The same actual position value is
signalled over and over again and
remains steady afterwards

• Encoder connection is not

correct

Current position is displayed as an
erratic ("jumping") value although
the shaft does not move

• Encoder cables are affected by

interference pulses

Recognition function supplies
varying information on the same
position; sometimes the axle
seems to jump to and fro.

Is there any mechanical
irregularity?

• Axle is tight, getting jammed, or

does not move smoothly for
any other reason

Position value is not in accordance
with amount of encoder rotation or
is erratic => shaft encoder is
defective

Check absolute encoder
(detach it, set multiplication and
demultiplication parameters to 1,
turn encoder by hand: the position
indicated must be in accordance
with the encoder revolutions)

• Encoder

defective

Advertising