Formation of the instance, Examples, 4 communication and protocol – NORD Drivesystems BU2100 User Manual

Page 19

Advertising
background image

4 Communication and Protocol

BU 2100 GB-2213

19

Coding of the FI parameters into the EtherNet/IP™ format is performed as follows:

FI parameter number to EtherNet/IP™

EtherNet/IP™ to FI parameter number

Class

= Table 10

Parameter number

= Attribute

Attribute

= FI parameter number

Sub-index

= Instance

Instance

= Sub-index

Formation of the instance

The formation of the instance depends on the structure of the relevant parameter.

The following applies for parameter set-dependent parameters without an array (e.g. P103):

Parameter set

Bit 1

Bit 0

Instance

1

0

0

0

2

0

1

1

3

1

0

2

4

1

1

3

The following applies for parameters which do not depend on a parameter set, but which have an
array (e.g.P465):

array

Bit 3

Bit 2

Bit 1

Bit 0

Instance

[-01]

0

0

0

0

0

[-02]

0

0

0

1

1

[-03]

0

0

1

0

2

[-04]

0

0

1

1

3

[-05]

0

1

0

0

4

The following applies for parameters which depend on a parameter set and also have an array (e.g.
P400):

array

Parameter set

array

Parameter set

Bit 3

Bit 2

Bit 1

Bit 0

Instance

[-01]

1

0

0

0

0

0

[-01]

2

0

0

0

1

1

[-01]

3

0

0

1

0

2

[-01]

4

0

0

1

1

3

[-02]

1

0

1

0

0

4

[-02]

2

0

1

0

1

5

Examples

Device

Parameter

array

Parameter set

Class

Attribute

Instance

Inverter 1

P103

--

1

101

103

0

Inverter 4

P103

--

3

104

103

2

Inverter 3

P465

[-01]

--

103

465

0

Inverter 3

P465

[-02]

--

103

465

1

Inverter 2

P400

[-01]

3

102

400

2

Inverter 2

P400

[-03]

1

102

400

12

Inverter 2

P400

[-03]

3

102

400

14

Advertising