Bus-specific information parameters (p18x), 2 frequency inverter parameters, Frequency inverter parameters – NORD Drivesystems BU2100 User Manual

Page 28: Active assembly, Mac adddress, Present ip address, Present ip sub-net mask

Advertising
background image

EtherNet/IP Bus module

– Supplementary manual options for NORD - Frequency Inverters

28

BU 2100 GB-2213

Bus-specific Information Parameters (P18x)

Parameter

Setting value / Description / Note

Device

Type

P180

... [-01]

... [-02]

Active Assembly

(Active Assembly)

SK xU4-EIP

8 bit

0 ... 255

Indicates the active assembly object

[-01] = Consumer Assembly

[-02] = Producer Assembly

P181

... [-01]

... [-06]

MAC Adddress

(MAC Address)

SK TU3-

SK xU4-

8 bit

0 ... 0xFF

Displays the Ethernet (MAC) address (unique identification of module)

[-

01] … [-03] = NORD manufacturer ID

F0 . 5F . 5A

[-

04] … [-06] = NORD free address range

xx . xx . xx

P185

... [-01]

... [-04]

Present IP Address

(Present IP Address)

SK TU3-

SK xU4-

8 bit

0 ... 255

Displays the present IP address

[-

01] … [-04] = IP Address

xxx . xxx . xxx . xxx

m

P186

... [-01]

... [-04]

Present IP Sub-net Mask

(Present IP Sub-net mask)

SK TU3-

SK xU4-

8 bit

0 ... 255

Displays the present IP sub-net mask.

[-

01] … [-04] = IP Sub-net mask

xxx . xxx . xxx . xxx

5.2 Frequency Inverter Parameters

Various parameters of the frequency inverter are relevant for the commissioning of the bus system or
the frequency inverter in the bus system and may need to be changed.

A detailed description of the inverter parameters can be found in the manual for the relevant frequency
inverter.

Para-
meter

Parameter name

Recommended setting

Remarks

SK 5xxE

SK

180E … SK 2xxE

P120

Option monitoring

Not available, or
not relevant for
SK TU3 modules

{1} = Auto

P509

Source Control Word

{8} = Ethernet TU

{3} = System bus

P510

Setpoint source

{0} = Auto

{0} = Auto

P513

Telegram timeout

{0.5} = 0.5s

{0.0} = Off

Do not set this value too low

P543

Actual BUS value

According to the
function:

According

to

the

function:

SK 54xE and SK

180E …

SK 2xxE: up to 5 actual
values each

P544

Actual BUS value 2

According to the
function:

Not available

Only SK

500E … 535E

Advertising