Power and and control terminal connection – NORD Drivesystems MI0300 User Manual

Page 19

Advertising
background image

Power and and control terminal connection

Migration Guide-GB-11.10.2012

19

More recent software files (GSD, EDS) are required for the field bus technology option SK TU4-xxx-
(C). Information about the master data for the device can be found in Section 5. Further software
planning information for conversion to the technology options for SK 2xxE frequency inverters can also
be found there.

3.2.1 Details of control terminals for connection units and customer interfaces

Control connections:

[21]

Dig. Input 1

(PTC input) (*)

[41]

+ 5V supply voltage

[40]

0V, GND

[41]

+ 5V supply voltage

[40]

0V, GND

[42]

+ 15V supply voltage

[74]

RS 485 interface: B (-)

[73]

RS 485 interface: A (+)

Termination resistor RS 485 On/Off
[02]

Signal relay (error)

[01]

Signal relay

[…] = Terminal No.

-B +B

-Br +Br

U V W

L1 L2 L3



Option

Customer unit

System connector M12 socket

Mechanical brake

External brake resistor

The polarity can be ignored.

(*) The digital inputs can be connected
with the internal 15 V or from the PLC
(7.5 – 33V DC). The data in "(...)"
represent the factory settings.

Fig. 3: Control terminals for connection unit SK TI 0/x-(C) for SK 300E

Customer side

Reference voltage +10 V (max. 10 mA)

[11]

AGND, 0V

[12]

Analog input -

[13]

Analog input +

[14]

Digital input 2 [Enable right]

[22]

Digital input 3 [Enable left]

[23]

Digital input 4 [Parameter set sw itching]

[24]

Supply voltage +15 V (max. 100 mA)

[42]

0...10V, 0/4…20mA
or
potentiometer:
2,0k

W...10kW

Floating contacts or

output of a PLC:
7,5...33V (low=0...3,5 V)

(Maximum terminal cross-section: 1,5 mm²)

Fig. 4: Control terminals for customer interface SK CU2-BSC-(C) for SK 300E

Customer side


Reference voltage +10 V (max. 10 mA)

[11]

AGND / 0V

[12]

Analog input 1

[14]

Analog input 2

[16]

Analog output 1

[17]

Digital input 2 [Enable right]

[22]

Digital input 3 [Enable left]

[23]

Digital input 4 [Parameter set switching]

[24]

Digital input 5 [fixed frequency 1]

[25]

Supply voltage +15 V (max. 100 mA)

[42]

0...10V, 0/4…20mA
or
potentiometer:
2,0k

W...10kW

Floating contact or
PLC output:
7,5...33V (low=0...3,5V)

(Maximum terminal cross-section: 1,5 mm²)

Fig. 5: Control terminals for customer interface SK CU2-BSC-(C) for SK 300E

Advertising