Module features – NORD Drivesystems TI 275900150 User Manual

Page 2

Advertising
background image

EtherNet/IP Bus module – SK TU3-EIP

2

TI 275900150 - 4913

Bus specification

EtherNet/IP

Max. 100 MBaud

Cable

Min. Ethernet CAT-5

Electrical isolation 500 V

eff

Max. cable length

100 m between two
modules

Bus connection

2 x RJ45

Shield

via RJ sockets high-

bus termination

Takes place automatically

Ohmic & capacitive to PE

Status display

8 LEDs

PE connection

via PE post-type connector

Topology*

Star*, ring, linear bus

(rating less than 24 V)

* additional switch for "star" topology required

Performance

Update interval for process data between module and frequency inverter

≤ 2.5 ms

Parameter read access to frequency inverter

≈ 15 ms

Parameters write access with storage on EEPROM

≈ 25 ms

Cycle times

≥ 1ms

Pos : 6 /T ec hnis che Inf or mationen/ SK xU x - Bus - Er wei ter ung en/ Et herNet /I P/Mer kmale [ EI P Allgemein] @ 3\ mod_1362996549668_388.doc x @ 61397 @ 5 @ 1

Module features

IO messages (process data connections)

One "Exclusive Owner“

Max. 2 “Listen Only” connections

Type "Cyclic", min cycle time 1 ms

Explicit messages

Yes

UCMM

Supported

DLR

Supported

Switch with two ports

integrated

Addressing via

DIP switches, module parameters, BOOTP and DHCP
possible

Access for NORD diagnosis tool via

diagnosis socket on the device (if available) and possibly
via frequency converter and
Ethernet protocols UDP or TCP/IP

Pos : 9 / Anl eit ung en/El ektr oni k/FU und St arter/ 3. / 4. Anzeige und Bedienung [ BU 0500 / BU 0200]/SK 5xxE/ 3. 2 Ü bersic ht der T echnologieboxen - 2- Mont age @ 1\ mod_1340712929975_388. doc x @ 28340 @ 5 @ 1

Advertising