Configuration

The basic configuration of the module primarily takes place via its DIP - switches. The DIP - switch
settings are read after a "Power On" of the module.

DIP switches

Meaning

12

11

10

9

8

7

6

5

4

3

2

1

Address

X

X

X

N

o f

u

nc

ti

on

0

0

0

0

0

0

0

0

0

X

X

X

0

0

0

0

0

0

0

1

1

X

X

X

0

0

0

0

0

0

1

0

2

X

X

X

0

-

-

-

-

-

-

-

-

X

X

X

1

1

1

1

1

1

1

1

255

Access rights for remote maintenance

0

Only read access to parameters possible.

1

Read and write access to parameters possible.

0

No control possible.

1

Control is possible.

0

TCP/IP open connection.

1

Secure TCP/IP connection.

1. IP address (DIP 1 - 8)

The final byte of the IP address can be set via this
switch and is controlled in parameter P185.
However, parameter P165 must be set to the default
setting (setting value "0").

2. Access rights for remote maintenance (DIP 10 – 12)

The module and the connected frequency inverter
can be accessed via Ethernet protocols TCP and
UDP via remote maintenance. The type of access is
determined via the DIP - switch with inputs 10 to 12.