Led displays – NORD Drivesystems TI 275900150 User Manual

Page 5

Advertising
background image

EtherNet/IP Bus module – SK TU3-EIP

TI 275900150 - 4913

5

LED displays

The operating statuses of the module tare visualised using LED indicators.

No.

Name

Colour

Meaning

1

MS

dual (red/green)

Module status

NS

dual (red/green)

Network status

DS

green

Device status

DE

red

Device error

2

Link

green

Link

Activity

yellow

Activity

Pos : 20 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Et herN et/ IP/LED Anz eigen- EtherNet/I P s pezifisc he LED [EIP Allgemein] @ 3\ mod_1363774926130_388. doc x @ 61840 @ @ 1

EtherNet/IP-specific LEDs

MS

(Module status)

Meaning

NS

(Network status)

Meaning

OFF

No operating voltage

OFF

No operating voltage

Flashing green

Module not configured

Flashing green

IP address configured but no CIP connection
available

green

Module working correctly

green

CIP connection(s) available

Flashing red

Minor error, faulty configuration

Flashing red

Time-out, an "exclusive owner connection"
has a time-out error

red

Unrecoverable error

red

Dual IP whose IP address is already being
used by the module

Flashing

red/green

Power up, self test

Flashing

red/green

Power up, self test

Link

(Green LED)

Activity

(Yellow LED)

Meaning

OFF

OFF

Module not ready, no control voltage.

No bus connection (check cable connection)

ON

OFF

Bus connection (cable connection) to another Ethernet device available

No bus activity available

ON

Flashing

(Blinking)

Bus connection (cable connection) to another Ethernet device available

Bus activity available

Pos : 21 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Allgemei n - Syst emübergreifend/ LED Anz eigen- N ORD s pezifisc he LED [EI P / PO L / ECT / PNT Allgemei n] @ 3\ mod_1363773424248_388. doc x @ 61815 @ @ 1

NORD-specific LEDs

DS

(Device status)

DE

(Device error)

Meaning
Long flash

= 0.5 s on / 1 s off

Short flash

= 0.25 s on / 1 s off

OFF

OFF

Module not ready, no control voltage.

ON

OFF

Module ready, no error, at least one frequency inverter is communicating via the system bus

ON

Short flashing

Module ready, but

One or more of the connected frequency inverters has fault status

Long flashing

OFF

Module ready and at least one other participant is connected to the system bus, but

no frequency inverter connected to system bus (connection may be interrupted)

one or more system bus clients has address error

Software incompatible (module software and FI software do not match - update required)

Long flashing

Short flashing

Flash interval

1 x - 1s pause

System bus is in status "Bus Warning"

Communication on system bus disrupted

No other clients available on system bus

Module not inserted correctly or no connection to the system bus

Frequency inverter has no supply voltage

Long flashing

Short flashing

Flash interval

2 x - 1s pause

System bus is in status "Bus Off"

the system bus 24V power supply was interrupted during operation

Long flashing

Short flashing

Flash interval

3 x - 1s pause

System bus is in status "Bus Off"

No system bus 24V power supply

Long flashing

Short flashing

Flash interval

4 x - 1s pause

Module error

see parameter P170

OFF

Short flashing

Flash interval

1…7 - 1s pause

System error, internal program sequence interrupted

EMC interference (observe wiring guidelines!)

Module defective

Advertising