Chapter 3: Installation

32 of 60

Figure 15: Display Calibration Menu Screen

3. Once in “Scale Calibration”, enter in the scale calibration weight value stamped on

the side of the weight.

4. The controller will prompt you to empty the weigh hopper and press “OK”.

5. After touching OK, the controller will display “PLEASE WAIT...”

6. Next, the controller will ask you to hang the calibration weight on the weight hopper

and press OK.

7. Finally, the controller will ask you to remove the calibration weight and press “OK”

to complete the calibration.

8. The controller will verify that the calibration was done correctly by showing

“Calibration Successful.”

9. Press “Done” until you have reached the Recipe screen.

Figure 16: Display Calibration Screen

Verifying Calibration (Recommended on a periodic basis to ensure accuracy)

1. From the “Recipe” Page, touch the Manufacturer’s icon and enter “5413”, then press

the “Enter” key.

2. Touch “Calibration” and then “Direct Scale Readout”

3. Ensure the weigh hopper is empty.

4. Locate the weight display for the load cell directly below “Current Bits.” Write

down the displayed value.

Enter in the Calibration
Weight

Press here to perform
the calibration

Go Back to the
Calibration Directory

Current Loadcell
Bits

Follow
Instructions

Go back to the
Setup
Directory