Sterlco GH-M Series Extrusion Control Weigh Hoppers User Manual

Page 48

Advertising
background image

Chapter 7: Appendix

48 of 60

Customer Responsibilities

Any sales, use, or other tax incident to the replacement of parts under this warranty is the
responsibility of the purchaser.

Annex B Information

The following design information is provided for your reference:

1. No modifications are allowed to this equipment that could alter the CE compliance
2. Ambient temperature:

40 degrees Celsius – Maximum (104 degrees

Fahrenheit)

3. Humidity range:

50% relative humidity

4. Altitude:

Sea

level

5. Environment:

Clean, dust-free and non-explosive

6. Radiation:

None

7. Vibration:

Minimal,

i.e.

machine

mounting

8. Special installation requirements:

Clean, dry compressed air 1 cfm @ 60 psi (1.7

m³/hr @ 4.14 bar)

9. Allowable voltage fluctuation:

+/- 10%

10. Allowable frequency fluctuation:

Continuous

+/- 1%

Intermittent +/-

2%

11. Nominal supply voltage:

120/1/60 or 220/1/50/60 (Verify on serial number tag)

12. Earth ground type:

TN (system has one point directly earthed through a
protective conductor)

13. Power supply should include a neutral power connection.
14. Over-current protection is supplied in the GH Hopper, but additional protection

should be supplied by the user.

15. The plug on the power cord serves as the electrical disconnect device.
16. Unit is not equipped with three-phase motors.
17. Functional identification
18. Cable support may be required for power cord, depending on final installation.
19. No one is required to be in the interior of the electrical enclosure during the normal

operation of the unit. Only skilled electricians should be inside the enclosure for
maintenance.

20. Doors can be opened with a screwdriver, but no keys are required.
21. Two-hand control is not required or provided.
22. All hoppers should be moved around and set in a place with a lift truck or equivalent.
23. There are no frequent repetitive cycles that require manual control

⎯repetitive

functions are automatic while the GH Hopper is operating.

24. An inspection report detailing the functional test is included with the GH Hopper.
25. The machine is not equipped with cableless controls.
26. Color-coded (harmonized) power cord is sufficient for proper installation.