Chapter 3: Installation

35 of 60

Alarm Setup

This screen allows the operator to configure the alarm settings for the rate monitor. To
configure the alarms do the following:

6. Enter the Setup Menu.

7. Once in the Setup menu, press “Alarm Setup.” This will take you to the “Alarm

Setup” screen.

Figure 18: Alarm Setup Screen


8. Press the “Done” key at the bottom to exit this screen. Min/Max Speed Limits restrict

the usable gravimetric range that the GH will permit in order to continue gravimetric
measurement. If the system becomes unstable for more than the “System unstable
alarm time” then an alarm will notify the operator. The Hopper% for low level
should always be set below the reload percentage (hopper setup page) and the
Hopper% for no material alarm should always be set below the low level %.

Network Setup

The rate monitor’s IP is the address of this rate monitor on a network. The rate monitor is
factory set up with an IP of 192.168.0.150 with a default subnet mask of 255.255.255.0.

In order to change the values, enter the Setup menu, press the “Network Setup” button and
change the values accordingly. Then the “send Ethernet config to module” button must be
pressed when changes are complete.

The “COEXPERT COM DISABLED” button is not used on a GH-M rate monitor. This
parameter is automatically configured if a COEXPERT AB system exist. Otherwise it should
always remain disabled!

Figure 31: Ethernet Setup Screen

Change monitor’s IP
Address and Subnet
Mask

Go back to Setup
Directory

Enable or Disable
the Ethernet
Module

Configurator

Change the Alarm
Silence Display

Changes weigh hopper
weight for no material

alarm.

Disable for GH-M,
GH-F, or GH without
Coexpert AB