Canon imagePROGRAF iPF6400S User Manual

Page 56

Advertising
background image

iPF6400S Basic Guide

56

C

ons

uma

bles
a

nd

M

ain

te

na

nc

e

C

le

an

in

g t

he

P

rint

er

Important

• Do not remove the Maintenance Cartridge or ink tanks during either Head Cleaning A or Head

Cleaning B.

Ink may leak or an error may occur.

• If printing does not improve even if you execute Head Cleaning B, try repeating Head

Cleaning B once or twice. If this still does not improve printing, the Printhead may have

reached the end of its useful life. Contact your Canon dealer for assistance.

Note

• By default, nozzles are checked at fixed intervals.

Configure the settings on the Control Panel menu in Nozzle Check.

(See "Menu Settings.")➔User's Guide


Perform cleaning as follows.

1

On the Tab Selection screen of the Control
Panel, press

◀ or ▶ to select the Settings/Adj.

tab (

).

Note

• If the Tab Selection screen is not displayed, press the Menu button.

2

Press the OK button.
The Set./Adj. Menu is displayed.

3

Press

▲ or ▼ to select Maintenance, and then press the OK button.

4

Press

▲ or ▼ to select Head Cleaning, and then press the OK button.

5

Press

▲ or ▼ to select Head Cleaning A or Head Cleaning B, and then press the OK button.

Head cleaning is now executed.

6

Print a test pattern to check the nozzles, and determine whether cleaning has cleared the
nozzles. (See "Checking for Nozzle Clogging.")➔User's Guide

Cleaning the Spectrophotometer Unit (option) Parts

Clean the Spectrophotometer Unit parts as follows.

Cleaning the White Calibration Tile

1

Turn the printer off.
(See "Turning the Printer On and Off.")➔User's Guide

Advertising