Important

Do not touch the (a) part of the White Calibration Tile Holder except
when removing the White Calibration Tile.
Doing so may cause the White Calibration Tile to fall, which can lead
to damage.

8

Push the (a) part of the White Calibration Tile Holder
and remove the White Calibration Tile.

Important

Never touch the white part of the White Calibration Tile.
If the white part is dirty, the printer may not be able to obtain the correct
color measurement results.

9

Wipe the surface of the White Calibration Tile clean with a dry, soft cloth.
If the white part is particularly dirty, use a damp cloth that you have wrung out completely to wipe the surface of
the White Calibration Tile clean and use a dry cloth to dry the surface.

10

Place the White Calibration Tile in the White Calibration
Tile Holder and mount it in the position shown in the di-
agram while pushing down on the (a) part.
When installing the White Calibration Tile, make sure it
is facing the appropriate direction.

11

Install the White Calibration Tile Holder on the Up-down
Unit as shown in the figure and move the holder in the
direction of the arrow to fix it in place.

Cleaning the Spectrophotometer Unit (option) Parts

iPF6450

User's Guide

Maintenance and Consumables

Cleaning the Printer

950