Question

Answer

When using the Spectro-
photometer Unit, which of
white or black should be
chosen in the White/Black
Backing Plate?

During normal usage, there is no restriction that you must always use white or you must always use black.

•

The White/Black Backing Plate complies with the measurement criteria defined in ISO 13655:2009.

•

When executing color calibration or color check using the Spectrophotometer Unit, we recommend that you
select white.
(See "Color Calibration Using the Spectrophotometer Unit (option).")

→P.833

(See "Color Checks Using the Spectrophotometer Unit (option).")

→P.835

•

If you are using paper that light passes through easily, we recommend that you select white.

•

If a color is used for one paper type that is different from the color that was used the previous time, it may have
an effect on the color measurement result.

If I am using the Spectro-
photometer Unit, can I
measure the colors of any
paper?

You might not be able to execute color measurement or might not be able to obtain the correct color measure-
ment results when using the following paper.

•

Colored paper

•

Paper where the surface is not even

•

Paper where the color density is low when printing