Agilent Technologies 664xA User Manual

Page 22

Advertising
background image

22 Remote Programming

Programming Some Power Supply Functions (continued)

1220

CALL IOENTER (PS,OEVENT)

'Read back event bit

1225

IF PCIB.ERR < > NOERR THEN ERROR PCIB.BASERR

1230

IF (OEVENT AND 1024) = 1024 THEN PRINT "Supply switched to CC mode."

1240

'Clear the status circuit

1245

CODES$ = "*CLS" :GOSUB 2000

1260

FOR I = 1 TO 100 :NEXT I

'Wait for supply to clear

1265

1260

'Disable output and save present state in location 2

1265

CODES$ = "OUTPUT OFF;*SAV 2"

:GOSUB 2000

1270

END

1275

2000

'Send command to power supply

2005

LENGTH = LEN(CODES$)

2010

CALL IOOUTPUTS (PS,CODES$,LENGTH)

'Send command to interface

2015

IF PCIB.ERR < > NOERR THEN ERROR PCIB.BASERR

ISETUP.BAS error trap

2020

RETURN

2025

3000

'Get data from power supply

3005

CALL IOENTERA (PS,OUTPUTS(1),MAX.ELEMENTS,ACTUAL.ELEMENTS)

3010

IF PCIB.ERR < > NOERR THEN ERROR PCIB.BASERR

3015

RETURN

******************************************************************************************************

IBM Controller Using National Interface

******************************************************************************************************
990

‘ --------------------- Merge DECL.BAS here ------------------------

1000

'Power Supply Variable = PS% ; Stand-Alone Address = 706

1005

CODES$=SPACE$(50):MODE$=SPACE$(5):OEVENT$=SPACE$(20)

1010

D$=SPACE$(60):OUTPUT$=SPACE$(40):BDNAME$=“PS%"

1015

DIM OUTPUT(2)

1020

1025

'Set up power supply interface for DOS driver

1030

CALL IBFIND(BDNAME$,PS%)

1035

IF PS%<O THEN PRINT "IBFIND Failed."

1040

CALL IBCLR(PS%)

1045

1050

'Program power supply to CV mode with following voltage and current

1055

CODES$ = "VOLTAGE 7.8;CURRENT 480”

:GOSUB 2000

1060

1065

'Query power supply outputs and print to screen

1070

CODES$ = "MEASURE:VOLTAGE?;CURRENT?"

:GOSUB 2000 :GOSUB 3000

1075

VOUT = OUTPUT(1)

1080

IOUT = OUTPUT(2)

1085

PRINT "The programmed levels are "VOUT" Volts and "IOUT" Amps"

1090

1095

'Program triggered current level to value insufficient to maintain

1100

'supply within its CV operating characteristic

1105

CODES$ = "CURR:TRIG 50"

:GOSUB 200

1110

1115

'Set operation status mask to detect mode change from CV to CC

1120

CODES$ = "STAT:OPER:ENAB 1024;PTR 1024"

:GOSUB 2000

1125

Advertising
This manual is related to the following products: