38 Language Dictionary

Initiate Subsystem

INIT
INIT:CONT


This subsystem enables the trigger system. When a trigger is enabled, an event on a selected trigger source causes the
specified trigging action to occur. If the trigger subsystem is not enabled, all trigger commands are ignored. If
INIT:CONT is OFF, then INIT enables the trigger subsystem only for a single trigger action. The subsystem must be
enabled prior to each subsequent trigger action. If INIT:CONT is ON, then the trigger subsystem is continuously enabled
and INIT is redundant.

Command Syntax

INITiate[:IMMediate]

INITiate:CONTinuous <bool>

Parameters

For INIT[:IMM] (None)

For INIT:CONT 0|1|OFF|ON

*RST Value

OFF

Examples

INIT INITIATE:IMMEDIATE

INIT:CONT 1 INITIATE:CONTINUOUS 1

Query Syntax

For INIT[:IMM] (None)

For INIT:CONT INIT:CONT?

Returned Parameters

<NR1>

0|1

Related Commands

ABOR <GET> *RST TRIG *TRG

Measure Subsystem

MEAS:CURR?
MEAS:VOLT?


This query subsystem returns the voltage and current measured at the power supply's sense terminals.

Query Syntax

MEASure:CURRent[:DC]? MEASure:VOLTage[:DC]?

Parameters

(None)

Default Suffix

A for MEAS:CURR? V for MEAS:VOLT?

Examples

MEAS:CURR?

MEAS:VOLT?

MEASURE:VOLTAGE:DC? MV

Returned Parameters

<NR3>

Advertising