VOLT:PROT


This command sets the overvoltage protection (OVP) level of the power supply. If the output voltage exceeds the OVP
level, then the power supply output is disabled and the Questionable Condition status register OV bit is set (see "Chapter 4 -
Status Reporting"). An overvoltage condition can be cleared with the OUTP:PROT:CLE command after the condition
that caused the OVP trip is removed. The OVP always trips with zero delay and is unaffected by the OUTP:PROT:DEL
command.

Command Syntax

[SOURce]:VOLTage:PROTection[:LEVel] <NRf+>

*Alternate Syntax

[SOURce]:VOLTage:PROTection:AMPLitude <NRf+>

Parameters

Table 3-1

Default Suffix

V

*RST Value

MAX

Examples

VOLT:PROT 21.5 VOLT:PROT:LEV MAX

VOLTAGE:PROTECTION:LEVEL 145E-1

Query Syntax

[SOURce]:VOLTage:PROTection[:LEVel]?
[SOURce]:VOLTage:PROTection [:LEVel]? MIN
[SOURce]:VOLTage:PROTection [:LEVel]? MAX

Returned Parameters

<NR3> VOLT:PROT? returns presently programmed OVP level.

VOLT:PROT? MAX and VOLT:PROT? MIN return the
maximum and minimum programmable OVP levels.

Related Commands

OUTP:PROT:CLE *RST *SAV *RCL

* Available to accommodate earlier power supply programs.

Command Summary


This summary lists all power supply subsystem commands in alphabetical order, followed by all common commands in
alphabetical order. See Table 3-1 for the command parameters accepted by each power supply model.

Command Summary

Command

Parameters

Subsystem Commands

ABOR

(none)

CAL

(See Appendix A in the Operating Manual)

[SOUR]:CURR[:LEV][:IMM][:AMPL]

<NRf+>[suffix]

[SOUR]:CURR[:LEV][:IMM][:AMPL]?

(none) |MIN|MAX

[SOUR]:CURR[:LEV]:TRIG[:AMPL]

<NRf+>[suffix]

[SOUR]:CURR[:LEV]:TRIG[:AMPL]?

(none) |MIN|MAX

[SOUR]:CURR:PROT:STAT

0 |l | ON|OFF

(SOUR]:CURR:PROT:STAT?

(none)

[SOUR]:DIG:DATA[:VAL]

<NRf>

[SOUR]:DIG:DATA[:VAL]?

(none)

DISP[WIND]:MODE

NORM|TEXT

DISP(WIND]:MODE?

(none)

DISP[:WIND][:STAT]

0 |l | OFF|ON

DISP[:WIND][:STAT]?

(none)

DISP[:WIND]:TEXT[:DATA]

<STR>

DISP[:WIND]:TEXT[:DATA]?

(none)

INIT[:IMM)

(none)

INIT:CONT

0 | l | OFF|ON

INIT:CONT?

(none)

Advertising