Configuring auto iris/auto focus resume settings – American Dynamics RAS917WLS-1 User Manual

Page 24

Advertising
background image

Changing the Freeze Frame Setting

1. Select

Pan/Tilt/Zoom/Sync Opts from the Dome Configuration Menu.

2. Move the highlight bar to Freeze Frame. Change the setting.

Select On to enable Freeze Frame. This freezes the current scene when presets or patterns are
selected.

Select Off to disable Freeze Frame. This displays the dome motion and lens adjustments when
presets or patterns are selected.

The default setting is Off.

3. Select

Exit. The Dome Configuration Menu appears. Continue with What To Do Next on page

2–7.

Configuring Auto Iris/Auto Focus Resume Settings

Normally, the camera’s iris and focus settings return to automatic mode when the dome moves a
minimum of one frame from its current pointing position. In some situations, you may want to
maintain specific iris and/focus adjustments based upon your surveillance needs.

Use the I/F Return to Auto setting to configure the auto iris and auto focus resume settings. Four
settings are available.

Setting

Description

ON

Both return to auto iris and return to auto focus settings are enabled.
Moving the dome resumes auto mode for both iris and focus changes.

OFF

Both return to auto iris and return to auto focus settings are disabled.
Moving the dome does not resume auto mode for iris and focus changes.

IRIS

Only return to auto iris is enabled. Return to auto focus is disabled.
Moving the dome resumes auto iris mode without changing focus settings.

FOCUS

Only return to auto focus is enabled. Return to auto iris is disabled.
Moving the dome resumes auto focus mode without changing iris settings.

Changing the Auto Iris/Auto Focus Resume Setting

1. Select

Pan/Tilt/Zoom/Sync Opts from the Dome Configuration Menu.

2. Move the highlight bar to I/F Return to Auto. Change the setting.

Select On to enable both resume auto iris and resume auto focus.

Select Off to disable both resume auto iris and resume auto focus.

Select Iris to enable resume auto iris only.

Select Focus to enable resume auto focus only.

The default setting is On.

3. Select

Exit. The Dome Configuration Menu appears. Continue with What To Do Next on page

2–7.

2–6

SpeedDome Ultra VII Day/Night Operator's Manual

Advertising
This manual is related to the following products: