Ad1650, Vm32/ad32, Vm96 – American Dynamics RAS917WLS-1 User Manual

Page 80: Ad2150/ad2350

Advertising
background image

VM32/AD32

Supported Protocols

SensorNet

RS-422

(1)

Maximum Presets

96 – SensorNet

4 – RS-422

Maximum Patterns

(2)

3

Quick Set Menu

Not supported

Address Range

1-32

Notes:

(1) Requires RCSN422 code converter.

(2) Patterns are limited by time and the number of

available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.

VM96

(1)

Supported Protocols

SensorNet

RS-422

Maximum Presets

Unlimited

(2)

Maximum Patterns

(3)

3

Quick Set Menu

Not supported

Address Range

1-96

Notes:

(1) Requires software version 5.2 or newer.

(2) Preset information is stored at the host, not the

dome.

(3) Patterns are limited by time and the number of

available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.

AD2150/AD2350

Supported Protocol

RS-422

(1)

Maximum Presets

16

(2)

or 60

(3)

Maximum Patterns

(4)

3

Quick Set Menu

Not supported

Address Range

1-32

Notes:

(1) Requires the AD2083-02 series code converter.

(2) Preset information is stored at the converter, not

the dome.

(3) Requires AD2083-02 with firmware version 0701-

11YB-156A or newer. Preset information is stored
in the dome, not the converter.

(4) Patterns are limited by time and the number of

available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.

AD1650

Supported Protocol

RS-422

(1)

Maximum Presets

16

(2)

or 60

(3)

Maximum Patterns

(4)

3

Quick Set Menu

Not supported

Address Range

1-128

(5)

Notes:

(1) Requires the AD2083-02 series code converter.

(2) Preset information is stored at the converter, not the

dome.

(3) Requires AD2083-02 with firmware version 0701-11YB-

156A or newer. Preset information is stored in the
dome, not the converter.

(4) Patterns are limited by time and the number of available

dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.

(5) Requires additional equipment to achieve these

numbers. A dome address within each group of 64 or 99
cameras is reserved as a global broadcast address.

A-4

SpeedDome Ultra VII Day/Night Operator's Manual