Supported Controllers

The following Manchester controllers are compatible with SpeedDome Ultra VII Day/Night:

Controller

Presets

Patterns

Quick Set Menu

Address Range

AD2150 64

3

No

1-64

MP48 64

3

No 1-64

AD168/MP168 64

3

No

1-64

AD2050/2052 64

3

No

1-64

This list of controllers is complete as of the time of publication. Other controllers may be supported.
Contact your Sales Representative for current information.

Performance Notes

The following considerations should be made when using the SpeedDome Ultra VII Day/Night
camera dome in a Manchester environment.

Using Auxiliaries

The dome provides four connections for auxiliaries. When used on a Manchester network, Auxiliaries
1 through 3 are supported. Auxiliary 4 is not supported.

Alarm Inputs

When operating on a Manchester network, the dome can be programmed to respond to any of the four
available alarm inputs. However, the dome cannot transmit alarm input states to the host controller. If
transmitting the alarm input states to the host controller is required, the alarm device must be wired
directly to the host controller.