DIAGNOSTICS

If the remote starter does not activate when the start button is pressed the park lights
will flash a diagnostic to indicate what shutdown input has been triggered. For example
when the start button is pressed the park lights flash 3 times slowly. Looking at the chart
below this would indicate that the system is in Service Mode, simply follow the
instructions listed in the owners manual on exiting Service Mode and the remote starter
will begin to function as normal.
PARK LIGHTS

STATUS LED

DIAGNOSTIC CODE

3 Flashes

Series of 3 Flashes

Door Opened “M” Models

3 Slow Flashes

LED’s On Solid

System Is In Service Mode

4 Slow Flashes

Series of 4 Flashes

Not in Reservation Mode “M” units

5 Flashes

Series of 5 Flashes

Hood Pin Opened

5 Slow Flashes

Series of 5 Flashes

Ignition On During Start Attempt

6 Flashes

Series of 6 Flashes

Brake Pedal Shutdown

7 Flashes

Series of 7 Flashes

Tach Lock-Out

DIAGNOSTIC MEMORY

LED Flashes

Diagnostic

5 Flashes

The system was shutdown by the brake switch input

6 Flashes

The system was shutdown by the hood pin input

7 Flashes

The system did not detect the tach signal.

8 Flashes

The system made 3 start attempts without starting

Being that the installer does not always see when the system shuts down or fails to
start, Diagnostic Memory will store in memory up to four shutdown codes.
This information can then be accessed to determine the source of the shutdown.
To Enter Diagnostic Mode:
Step 1 -
Turn the ignition on then turn off. Press the Program Button and release.
Step 2 - The system will respond with three park light flashes and the siren will chirp

the same number of times as the events in memory.
Maximum four events, four chirps

NOTE:

If the siren does not chirp, there are no events in memory.

Step 3 - Press the Program Button once to view the last shut down code. The siren

will chirp once to confirm code one.
If the horn does not chirp, there are no codes in memory.

Step 4 - The LEDs on the antenna will flash a code corresponding to a shut down trigger.

Press the Program Button again to check the second code.

The siren will chirp twice to confirm code two.

Step 5 - To Clear Diagnostic Memory. While in Diagnostic Mode press and hold the

Program Button for five seconds.
The park lights will flash and the siren will chirp once.

NOTE:

Once diagnostic memory has 4 shutdown events in memory, the system will not

Record any further shutdown events until the system memory has been cleared.