Setting the error log collection level -75 – HP XP Racks User Manual

Page 137

Advertising
background image

The dynamic I/O path control function can be set for each storage system or

LU. The checking interval for reviewing the switching status information can

also be set in order to properly follow the switching of controllers performed

by the storage system,

The following is an example of setting the dynamic I/O path control function:

# /usr/DynamicLinkManager/bin/dlnkmgr set -dpc on -pathid 000001 -lu

# /usr/DynamicLinkManager/bin/dlnkmgr set -dpcintvl 10

Specify "on" to enable the dynamic I/O path control function, or "off" to

disable the function. For the -pathid parameter, specify an LU, or the ID of a

path connected to the storage system. For the -dpcintvl parameter, specify

the checking interval (in minutes) for reviewing the information about the

switching of controllers performed by the storage system.

Setting the Error Log Collection Level

The error log (the HDLM manager log (dlmmgrn.log (n indicates a file

number from 1 to 16)) collection level can be set.

The following table lists and describes the values for the error log collection

level setting.

Table 3-13 Values for the Error Log Collection Level Setting

Value

Description

0

No error logs are collected.

1

All information for errors of the "Error" level or higher is

collected.

2

All information for errors of the "Warning" level or higher is

collected.

3

All information for errors of the "Information" level or

higher is collected.

4

All information for errors of the "Information" level or

higher (including maintenance information) is collected.

If an error occurs, you might have to set the error log collection level to 1 or

higher to collect any log information.

The higher this value is set, the more information that will be output. As the

amount of log information to be output increases, it will take less time to

overwrite the old error log information with the new information.

The following is an example of setting up the error log collection level by

using a command:

# /usr/DynamicLinkManager/bin/dlnkmgr set -ellv 2

Specify the error log collection level as a number.

Creating an HDLM Environment

3-75

Hitachi Dynamic Link Manager User Guide for AIX®

Advertising