When you change some settings, you can display information about all of

HDLM function settings. The following is an example of executing the

command:

# /usr/DynamicLinkManager/bin/dlnkmgr view -sys -sfunc

HDLM Version : x.x.x-xx

Service Pack Version :

Load Balance : on(extended lio)

Support Cluster :

Elog Level : 2

Elog File Size(KB) : 1000

Number Of Elog Files : 5

Trace Level : 1

Trace File Size(KB) : 2000

Number Of Trace Files : 10

Path Health Checking : on(10)

Auto Failback : on(10)

Intermittent Error Monitor : on(2/20)

Dynamic I/O Path Control : off(10)

KAPL01001-I The HDLM command completed normally. Operation name =

view, completion time = yyyy/mm/dd hh:mm:ss

#

After you have set up the collection of audit log data, use the following

command to make sure that the setting has been specified correctly:

# /usr/DynamicLinkManager/bin/dlnkmgr view -sys -audlog

Audit Log : on(6)

Audit Log Category : all

Audit Log Facility : local0

KAPL01001-I The HDLM command completed normally. Operation name =

view, completion time = yyyy/mm/dd hh:mm:ss

#

Setting up Integrated Traces

When HDLM is used, the dlnkmgr command logs are output to the integrated

trace information files of Hitachi Network Objectplaza Trace Library

(HNTRLib2) (/var/opt/hitachi/HNTRLib2/spool/hntr2n.log (n indicates a

file number)).

If a lot of integrated trace information is output, the older information might

end up getting deleted in a very short amount of time. Also, if a large amount

of integrated trace information is suddenly all output at the same time, any

integrated trace information that is overflowing the buffer might not be saved

into the integrated trace files. To save as much information as possible,

change the settings for Hitachi Network Objectplaza Trace Library, increasing

the integrated trace file size and buffer size. Note that if the values are too

large, it will place a heavy load on the system. When determining these

values, be sure to consider these operational tradeoffs.

The following table lists the default values and recommended values for the

integrated trace file setting.