Replacing a fibre channel switch, Replacing a fibre channel switch -29 – HP XP Racks User Manual

Page 195

Advertising
background image

Depending on the NPIV option setting for the dlmodmset utility checked in

step 1, execute one of the following commands:

¢

If the NPIV option is set to off:
Specify the HBA adapter number and bus number, and then execute

the command shown below. The following example shows how to

place the path in Offline (C) status when the path goes through an

HBA whose HBA adapter number is 08 and whose bus number is 11:

# /usr/DynamicLinkManager/bin/dlnkmgr online -hba 08.11

¢

If the NPIV option is set to on:
Use the fscsi number to execute the command below. The following

example shows how to place the path in Offline (C) status when the

path goes through fscsi number 1 (fscsi1):

# /usr/DynamicLinkManager/bin/dlnkmgr online -hba 00.01

5

.

Execute the following command to check the path information:

# /usr/DynamicLinkManager/bin/dlnkmgr view -path

For details about path information, see

view (Displays Information) on

page 6-32

.

Replacing a Fibre Channel Switch

If there are multiple active paths for an LU, you can replace a desired Fibre

Channel switch while running your applications by placing offline only the

path that goes through the Fibre Channel switch to be replaced and by using

other Fibre Channel switches to continue access.

Note

The following procedure is only for replacing a Fibre Channel switch.

To replace a Fibre Channel switch:

1

.

Execute the following command to find the fscsi number that

corresponds to the path that goes through the Fibre Channel switch that

is to be replaced (the path that goes through the HBA to which the Fibre

Channel switch is connected):

# lsdev -C | grep fscsi

The following are execution examples:

fscsi0 available 1H-08-02 FC SCSI I/O controller protocol device

fscsi1 available 11-08-02 FC SCSI I/O controller protocol device

In the second line of the above examples, 11 in 11-08-02 indicates the

bus number and 08 indicates the HBA adapter number. If the Fibre

Channel switch is connected to this HBA, the corresponding fscsi

number is 1.

2

.

Execute the dlmodmset utility for setting the HDLM execution environment

ODM to check the NPIV option setting.

HDLM Operation

4-29

Hitachi Dynamic Link Manager User Guide for AIX®

Advertising