Copy Pace: Allows you to specify the pace (speed) for an initial copy activity for one volume.
The default is Low.

Low: The speed of the initial copy activity is slower than Medium and High.

Medium: The speed of the initial copy activity is faster than Low and slower than High.

To specify Medium, ensure that the amount of update I/Os (that is, write requests from
hosts to primary data volumes) is 10 MB/s or less per one parity group. If it exceeds 10
MB/s, data volume pairs may become split (suspended).

High: The speed of the initial copy activity is faster than Low and Medium.

To specify High, ensure that update I/Os (that is, write requests from hosts to primary
data volumes) will not occur. If update I/Os occur, data volume pairs may become split
(suspended).

NOTE:

The secondary storage system administrator cannot specify this option.

Unit of Path Watch Time: Allows you to specify the unit of path watch time. You can specify
one of the following settings: minute, hour, or day.

Path Watch Time: Allows you to specify the interval from when a path gets blocked to when
a mirror gets split (suspended).

This value must be within the range of 1 to 59 minutes, 1 to 23 hours, or 1 to 30 days. You
can specify a numeric value in Path Watch Time.

NOTE:

Make sure that the same interval is set to both the master and restore journal groups

in the same mirror, unless otherwise required. If the interval differs between the master and
restore journal groups, these journal groups will not be suspended simultaneously. For example,
if the interval for the master journal group is 5 minutes and the interval for the restore journal
group is 60 minutes, the master journal group will be suspended in 5 minutes after a path
gets blocked, and the restore journal group will be suspended in 60 minutes after a path gets
blocked.

NOTE:

If you want a mirror to split (suspended) immediately after a path gets blocked, ask

HP technical support to set system option mode 448 to ON and set system option mode 449
to OFF.

Table 40 System Option Modes

Description

Mode

ON: If the SVP detects a blocked path, the SVP assumes that an error occurred, and then
immediately splits (suspends) the mirror.

OFF: If the SVP detects a blocked path and the path does not recover within the specified
period of time, the SVP assumes that an error occurred, and then splits (suspends) the mirror.

NOTE:

The mode 448 setting takes effect only when mode 449 is set to OFF.

448

ON: The SVP does not detect blocked paths.

OFF: The SVP detects blocked paths and monitors the time until the mirrors get split (suspended).

449

Forward Path Watch Time: Allows you to specify whether to forward the Path Watch Time
value of the master journal group to the restore journal group. If the Path Watch Time value