Table 25 Pair Status and Operation after Recovery of the Primary Site

Perform this operation before transferring business tasks back
to the Primary Site

Invalid Pair Status

1.

Make sure that the status of the pair in the primary site is
Suspend.

2.

Release the Universal Replicator for Mainframe pair from the
primary site.

3.

Make sure that all the pairs belonging to the journal group
in the primary site are released.

4.

Create a Universal Replicator for Mainframe delta resync
pair that extends from the primary site to the Universal
Replicator for Mainframe secondary site.*

Primary site: Pending
Duplex

Universal Replicator for
Mainframe secondary site:
Hold

1.

Release the Universal Replicator for Mainframe pair from the
primary site.

2.

Make sure that all the pairs belonging to the journal group
in the primary site are released.

3.

Create a Universal Replicator for Mainframe delta resync
pair that extends from the primary site to the Universal
Replicator for Mainframe secondary site.*

Primary site: Duplex

Universal Replicator for
Mainframe secondary site:
Hold

Change the status of the Hlde pair back to Hold. For more
information, see

“Restoring a Pair of Data Volumes” (page 206)

.

Primary site: Hlde

Universal Replicator for
Mainframe secondary site:
Hold

1.

Release the pair in Hold status from the Universal Replicator
for Mainframe secondary site.

2.

Create a Universal Replicator for Mainframe delta resync
pair that extends from the primary site to the Universal
Replicator for Mainframe secondary site.

1

Primary site: Simplex

Universal Replicator for
Mainframe secondary site:
Hold

1

For information about requirements for creating the pair, see

“Requirements for Creating Universal Replicator for

Mainframe Pair for the Delta Resync Operation” (page 90)

.

* For information about requirements for creating the pair, see

“Requirements for Creating Universal

Replicator for Mainframe Pair for the Delta Resync Operation” (page 90)

.