Table 35 Operations Displayed in the History Window (continued)

Descriptions

Displays

An operation for releasing a pair has been started at the secondary storage system.
The status of the data volume pair will change from Hold to Simplex.

Status Change by RCU(Hold to
Simplex; Delete Pair Start)

The status of the secondary data volume was changed to Hold because of a delta
resync operation.

Status Change to Hold

The storage system could not identify the type of operation.

Unknown

NOTE:

The history information (that is, rows in the list) might not appear in chronological descending
order. To sort the information in descending (or ascending) order, click a header in the list.

The History window can show history information for up to 524,288 operations. However,
the window can only display up to 16,384 operations at one time. To display the remaining
operations, click the Previous or Next button.

The History window does not provide history information older than seven days. Also, if the
number of operations exceeds 524,288, the oldest operations are deleted in chronological
order to keep the number at 65,535, even if the operations occurred within the last seven
days. The history file always contains the most recent operations up to a maximum of 65,535
operations. The history information for an entire week may not always be available.

If a failure occurs with two or more data volume pairs at the same time, the number of pairs
showing Suspend Pair(Failure)or Ready for Delta resync(Failure) may not match the actual
number of pairs where the failure occurs.

The copy time might not be shown in the Copy Time column, even though AddPair Complete
or ResumePair Complete is shown in the Operation column. In such case, you can confirm the
copy time on the volume list in the Pair Operation window.

Optional Operation Window

The Optional Operation window (see

Figure 57 (page 132)

) allows you to set options.

Optional Operation Window