Deleting logical paths – HP StorageWorks XP Remote Web Console Software User Manual

Page 155

Advertising
background image

Table 38 Logical Path Status

Remarks

Status

This path has been successfully established and can be used for Universal Replicator
for Mainframe remote copy activities.

Normal

An operation for configuring or deleting this logical path is in progress.

Nothing

An error occurred with the initialization of a connection between the local and the
remote storage system. The probable causes are:

No cable is connected to the local storage system.

No cable is connected to the remote storage system.

No cable is connected to the network device that comes between the local and
the remote storage system.

Initialization Failed

This indicates one of the following statuses:

A timeout error has occurred between the primary and the secondary storage
systems.

A logic error is detected between the primary and the secondary storage systems.

Communication Time
Out

The local storage system rejected the function for configuring a logical path
connection. All logical path resources in the local storage system might be used
for other connections.

Resource Shortage
(Port)

The remote storage system rejected the function for configuring a logical path
connection. All logical path resources in the remote storage system might be used
for other connections.

Resource Shortage
(Pair-Port)

The serial number of the storage system connected to this logical path does not
match the serial number specified by the Add DKC window.

Serial Number
Mismatch

The port is not an initiator port.

Invalid Port

This indicates one of the following statuses:

The specified port number is incorrect.

The port in the remote storage system is physically disconnected from the local
storage system.

Pair-Port Number
Mismatch

The port on the remote storage system is not an RCU target port.

Pair-Port Type
Mismatch

A communication timeout error has occurred on the path between the primary and
the secondary storage systems.

Communication Failed

Deleting Logical Paths

Before deleting logical path(s), make sure that the remaining number of logical paths will be greater
than the minimum number of paths setting. The delete path operation will fail if the number of
remaining paths is equal to or less than the minimum number of paths.

To delete logical path(s), follow the procedure below. Not only the primary storage system
administrator but also the secondary storage system administrator can perform this operation.

1.

Ensure that the Remote Web Console main window is in Modify mode.

For detailed information about how to do this, see the HP StorageWorks XP24000/XP20000
Remote Web Console User's Guide
.

2.

Ensure that the DKC Operation window is displayed.

3.

In Display, select DKC.

Deleting Logical Paths

155