Starting the FCU GUI for UNIX

To start the FCU GUI program for UNIX-based platforms:

1.

At the UNIX command line prompt, enter: fcu [-nc] [param]

The -nc option (nc = no checking) tells FCU to execute all specified Data Exchange operations
without requesting confirmation for FCU parameters or checking for existing FXmto target files.
To bypass these confirmations, enter -nc.

The param option tells FCU whether to use the FCU parameter definition file or a specific FCU
initiation parameter set to perform Data Exchange operations. The param option must have one
of the following three values:

• [blank]. To use the default FCU parameter definition file (fcudata.param in the current

directory), leave the param option blank (do not enter anything).

• file_name. To use a different FCU parameter definition file, enter the file name with complete

path (absolute or relative) if not in the current directory.

• -P + parameters. To perform one specific Data Exchange operation, enter -P followed by

the FCU initiation parameter set (for example, mto VSN:dataset targetfile No No
No

) for the desired Data Exchange operation. The -P option requires the -nc option.

For example:

• To use the default FCU parameter definition file and check the parameters and FXmto target

files, enter: fcu

• To use the default FCU parameter definition file and perform all operations without checking

parameters or FXmto target files, enter: fcu -nc

• To use a different FCU parameter definition file and perform all operations without checking

parameters or FXmto target files, enter: fcu -nc filename

• To perform one specific Data Exchange operation, enter: fcu -nc -P [parameters]

NOTE:

The following warnings may appear during FCU startup. These warnings do not affect FCU
and can be ignored.

WARNING: Missing characters in String to FontSet conversion.

WARNING: Cannot convert string “-dt-interface

system-medium-r-normal -m*-*-*-*-*-*-*-*-*” to type FontSet.

2.

The FCU GUI program now starts loading. The FCU version and copyright screen (see

Figure

66

on page 107) is displayed while FCU is loading. When FCU is finished loading, the FCU main

panel is displayed.