Get a dataset attribute: dataset_GetFileInformation, dataset_FindFirstFile,
dataset_FindNextFile

, dataset_FindClose

Programming Restrictions:

You cannot use Data Exchange from the Signal Handler.

The following words are reserved words. When the user creates a program using FAL, these words
cannot be used for function names, variable names, symbol names, or constant names:
• dataset
• fast_
• GetVolSers

Do not mix the Data Exchange multi-thread function with the user API for multi-thread and the user
API for non-multi-thread.

This function is only applicable for AIX and Windows (32-bit versions).

You do not need a volume definition file when the user uses the API for multi-thread.

You can open multiple datasets simultaneously using the multi-thread API:
• dataset_AllocGlobal...: Reserve an area for information for dataset A.
• dataset_AllocGlobal...: Reserve an area for information for dataset B.
• datset_Open...: Open dataset A.
• dataset_Open...: Open dataset B.

Information Storage Area

Format: memError= dataset_AllocGlobal(dgpp,derrno,malloc,free) (

Table

52

on page 137)

Table 52 Arguments, Types, and Descriptions for Information Storage Area

Description

Type

Argument

Global memory area

void

1

dgpp

An error information stored area

long

2

derrno

malloc()

void

1

malloc

free()

void

2

free

int

memError

Return value:

Abnormal end

0

1

You must issue this function before dataset_Open() and dataset_FindFirstFile().

2

When you issue this function, you must issue dataset_FreeGlobal() in the end process.

Arguments:
• dgpp: Global memory area stored area
• derrno: Return an address stored FAL error code
• malloc: Specify an address of malloc function. Specify as malloc.
• free: Specify an address of free function. Specify as free.

Return Value:
• When this function ends normally, it returns a 1.

HP StorageWorks P9000 Data Exchange User Guide