Troubleshooting

For general troubleshooting information, see the HP StorageWorks Disk Array Owner’s Guide for the
storage system.

When errors are detected, error codes and messages are displayed and/or logged.

Table

64

on page 149,

Table 65

on page 150, and

Table 66

on page 154 list the FAL and FCU error codes

and provide instructions for resolving the error conditions.

If you have a problem with the Data Exchange software, first make sure that the problem is not being
caused by other open-system software or hardware, and try rebooting the open-system server.

For FCU operations, make sure that the Data Exchange volume definition file and FCU initiation
parameters are correct.

Table 64

on page 149 lists potential error conditions in Data Exchange and

provides instructions for resolving each condition.

If you are still unable to resolve an error condition, ask your HP support representative for help or call
HP technical support for assistance (see

Error Codes and Messages

” on page 150).

Table 64 Troubleshooting

Recommended Action

Error Condition

Make sure that the devices have been mounted. If mounting is done during
an FCU operation, the results cannot be guaranteed because error information
may not be reported to FCU.

UNIX files in non-HP storage
systems could not be ac-
cessed.

Define a path to the Xmlibrary as follows:

1.

For C shell, add the following line to the .cshrc file in the home directory:

setenv LD_LIBRARY_PATH /usr/dt/lib:$LD_LIBRARY_PATH

2.

For non-C shell, add the following two lines to the .dtprofile file in
the home directory:

LD_LIBRARY_PATH=/usr/dt/lib:$LD_LIBRARY_PATH

export LD_LIBRARY_PATH

Solaris system reports an error
indicating libXm.so.xx is not
found.

Remove all space lines from the FCU parameter definition files. FCU versions
01-01-24 and earlier supported space lines when run without the GUI. FCU
versions 01-01-36 and later do not support space lines.

Windows systems only:
FCU reports errors when
accessing an FCU parameter
definition file.