Each control statement must be completely specified on one line. A control statement cannot extend
over two or more lines.

Control statement examples

To output the log data with acquisition dates in the range from 2013/03/24 00:00 to 2013/03/24
23:59, specify as follows.

RANGE STARTTIME(2013/03/24,00:00:00) ENDTIME(2013/03/24,23:59:59)

To output the log data with acquisition dates in the range from 2013/03/24 00:00 to 2013/03/24
23:59 and with the job names USER01T or USER01, specify as follows.

RANGE STARTTIME(2013/03/24,00:00:00) ENDTIME(2013/03/24,23:59:59)

SELECT COND(JOBNAME,EQ,'USER01T')

SELECT COND(JOBNAME,EQ,'USER01')

Output format of the event log data output tool

The following table shows the output format of the event log data output tool.

Table 54 Output format of the event log data output tool

Description

Output contents

Length

Offset

Output data length = 32 + log data length (

n

)

Output data length

2

+X'00'

'0000'X

Reserved

2

+X'02'

For the first record: '01'X
For records other than the first record: '00'X

Division flag 1

1

+X'04'

For the last record: '01'X
For records other than the last record: '00'X

Division flag 2

1

+X'05'

The time-stamp specified by the system logger service when
the log data is output

GMT time-stamp (TOD format)

8

+X'06'

The time-stamp specified by the system logger service when
the log data is output

Local time-stamp (TOD format)

8

+X'0E'

'00 ... 00'X

Reserved

10

+X'16'

--

Log data

n

+X'20'

Collecting event logs without using the system logger service

If the system logger service is not used, log data is output to a Smart Manager for Mainframe log
dataset.

Allocating log datasets without using the system logger service

Allocate two sequential datasets (log datasets) to each job to collect logs.