Ktinschk, Return codes generated by the ktinschk command, Output items of the ktinschk command – HP XP Command View Advanced Edition Software User Manual

Page 173

Advertising
background image

READY

KTERCODE 6A13

Error details:

The command could not be executed because a remote command was executed

while the command device was not defined.

Type of error:

Others.

KTINSCHK

Function

Checks the setting items required for setup for incomplete or incorrect information, and then outputs
a message showing the check results and the settings.

Command type

TSO/E command

Format

KTINSCHK

Return codes

The following table lists and describes the codes returned when the

KTINSCHK

command terminates.

Table 31 Return codes generated by the KTINSCHK command

Meaning

Return code

There were no problems with the settings.

0

There were problems with the settings.

8

A processing error occurred during command execution.

32

Output items

The following table lists and describes the items output when the

KTINSCHK

command is executed,

in the order in which they are output.

Table 32 Output items of the KTINSCHK command

Description

Output item

OK

: View permission required for using CLI commands is as-

signed to the reference profile or the operation profile.

FAULTY

: View permission required for using CLI commands is

assigned to neither the reference profile nor the operation profile.

Security Settings

User Guide