Procedure

1.

Log on to the TSO/E terminal.

2.

Enter the following commands.

• To output an ABEND dump to the spool:

ALLOC DD(SYSABEND) SYSOUT(SYSOUT-class)

• To output an ABEND dump to a dataset:

ALLOC DD(SYSABEND) DS(dataset-name)

3.

Execute a CLI command.

4.

If the CLI command terminated abnormally and the system returned to the READY mode, press
the Enter key.

If you enter a TSO/E command without pressing the Enter key, ABEND dumps might not be
output.

Log types for Smart Manager for Mainframe

Of the acquired trace information, only the information that must be presented to the user is output
to a log.

The following table shows the log types for Smart Manager for Mainframe, the collected information,
and the output destinations.

Table 51 Log types for Smart Manager for Mainframe

Output destination

Collected information

Log type

When the system logger service is used:
DASD-only log stream for the system logger ser-
vice

When the system logger service is not used:
Log dataset for Smart Manager for Mainframe

Messages

Only in the case of an I/O error, parameter
information, return information, and sense byte
information for that I/O

Time-stamps

Command parameter information

Event log

ISPF log dataset

Transaction logs in the ISPF panel

Messages that were output during command
execution

ISPF log

SYSLOG

CLI command name

Parameters

Execution results

CLI command-execution
log

Related topics

Collecting event logs

, page 205

Collecting ISPF logs

, page 218

Collecting the CLI command-execution log

, page 219

Collecting trace information and logs

204