Procedure

1.

Enter the

FORCE IXGLOGR,ARM

command to stop the system logger service.

2.

Enter the

S IXGLOGRS

command to restart the system logger service.

3.

Use the IXCMIAPU utility with the

DELETE LOGSTREAM NAME(log_stream_name)

parameter

specified to delete the log stream.

The log dataset is deleted when the log stream is deleted. For details, see the manual MVS Setting
Up a Sysplex
.

4.

Re-define the log stream.

Related topics

Starting the system logger service

, page 208

Parameters specified when a log stream is defined

, page 208

JCL example for deleting a log stream

, page 210

Disk space requirements for the event log when the system logger service is used

The following table shows the amount of log data when the system logger service is used to output
the event log.

Table 53 Amount of event log data when the system logger service is used

Number per command

Size

#1

Types of event log data

Number of output messages

68 + message length

#2

Messages (excluding messages output from the
ISPF panel and scripts)

Number of I/O errors

68 + CCW length

#2

Only in the case of an I/O error, parameter in-
formation for the CCW for that I/O

Number of I/O errors

224

Only in the case of an I/O error, return informa-
tion for that I/O

Number of I/O errors

224

Only in the case of an I/O error, sense byte in-
formation for that I/O

2

96

Time-stamps

1

224

Command parameter information

#1

The size is rounded up to a multiple of 32 before being output.

#2

The maximum length is 256 bytes.

Estimating the staging dataset

Estimate the disk capacity based on the amount of event log data.

Estimating the log stream dataset

Estimate the disk capacity based on the amount of offloaded event log data and the retention period.

Collecting trace information and logs

212