Fmid for smart manager for mainframe components – HP XP Command View Advanced Edition Software User Manual

Page 32

Advertising
background image

8.

Re-execute

HPQKT4AP

after the

CHECK

operand is deleted.

SMP/E APPLY is executed and the provided datasets are installed in the target library.

Run the Smart Manager for Mainframe instance that was installed in the target library. If no errors
occur, back up Smart Manager for Mainframe to the distribution library.

The following table shows the keyword (

FMID

) that is required for installing with SMP/E.

Table 4 FMID for Smart Manager for Mainframe components

Function name

FMID

Smart Manager for Mainframe

CHKLnnn

Note:

The

nnn

part of

CHKLnnn

varies depending on the version.

Postrequisites

Settings required for using CLI commands (registration for authentication)

Related topics

Settings required for using CLI commands (registration for authentication)

, page 33

Backing up Smart Manager for Mainframe to the distribution library

, page 54

Appendix E

, page 281

Installing directly from the provided datasets in the target library

Perform an installation directly from the provided datasets in the target library, without using SMP/E.

Procedure

1.

Edit the sample JCL

HPQKTSIN

for installation in accordance with the user installation environment.

Details are provided at the beginning of the sample JCL.

The sample JCL is stored in the

HP.CHKLnnn.F1

dataset (the

nnn

part varies depending on the

version). If you edited the

RECVUPLD

job to change the output destination dataset name for the

TSO/E

RECEIVE

command, the sample JCL is stored in the dataset after the change.

2.

Execute

HPQKTSIN

.

The contents of the provided datasets are registered in the target library.

Postrequisites

Settings required for using CLI commands (registration for authentication)

Related topics

Settings required for using CLI commands (registration for authentication)

, page 33

Appendix E

, page 281

Installation and setup

32