Snmp – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 64

Advertising
background image

Command line 64

Item

Description

(required)

server port. The format of the ConnectionId is <ProfileName:PortNumber>.

Network (required) The name of a valid Ethernet network on which the mapping exists
Properties

VLanID (optional)

The new VLAN ID to be used for the mapping server port to network. Valid values
include 1 to 4094.

Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in

an Ethernet network connection is allowed to handle untagged packets. The default
value is "false". If a shared uplink set is being used, the untagged network is the
same as the native network if present, but any network can also be configured to

handle untagged packets.
When changing a network untagged option from true to false, the user is required
to provide a VLanID if the global option SharedServerVLanId is set to "false".

Examples

->set server-port-map MyProfile:1 Network1 VLanId=100

Modifies the VLAN ID of an existing server port network mapping

->set server-port-map MyProfile:1 Network1 Untagged=true

Modifies the existing server port network mapping to handle untagged packets

Item

Description

show server-port-map Display a server port network mapping. This command cannot be used if the

domain setting, VLanTagControl, is set to "Tunnel".

Syntax

show server-port-map [<ConnectionID> | *]

Parameter

ConnectionID

(optional)

The reference ID of an existing enet-connection associated with a profile and a

server port. The format of the ConnectionId is <ProfileName:PortNumber>.

Examples

->show server-port-map

Lists all the server port mappings

->show server-port-map MyProfile:1

Displays the server port mapping for a profile

->show server-port-map *

Displays detailed output of all the server port mappings

snmp

View and modify the SNMP configuration for VC-Enet and VC-FC modules, and add, modify, and remove

SNMP trap configurations related to trap destinations.
Supported actions: set, show, help

Item

Description

set snmp

Modify the VC SNMP configuration.

Syntax

set snmp <Type> [ReadCommunity=<ReadCommunityString>]

[SystemContact=<SystemContact>] [Enabled=<true|false>]

[SmisEnabled=<true|false>]

Parameter

Type (required)

Indicates which SNMP configuration to modify. Valid values include "Enet" and

"FC".

Advertising