Creating server profiles, Adding enet-network connections to a profile, Adding iscsi connections to a profile – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 118

Advertising
background image

Configuring the Virtual Connect domain using the CLI 118

and SAN boot settings and connects the appropriate networks and fabrics. Server blades that have been
assigned a profile and remain in the same device bay do not require further Virtual Connect Manager

configuration during a server or enclosure power cycle. They boot and gain access to the network and fabric
when the server and interconnect modules are ready.
If a server blade is installed in a device bay already assigned a server profile, Virtual Connect Manager

automatically updates the configuration of that server blade before it is allowed to power on and connect to
the network.
If a server blade is moved from a Virtual Connect-managed enclosure to a non-Virtual Connect enclosure,
local MAC addresses and WWNs are automatically returned to the original factory defaults. This feature
prevents duplicate MAC addresses and WWNs from appearing in the data center because of a server blade

redeployment.

IMPORTANT:

Before assigning a profile, unassigning a profile, or modifying a profile, be sure to

review the "Server blade power on and power off guidelines (on page

122

)."

Creating server profiles

To create a new server profile, use the add profile command:

>add profile MyProfile

After an enclosure is imported into a Virtual Connect domain, server blades that have not been assigned a
server profile are isolated from all networks to ensure that only properly configured server blades are
attached to data center networks.
A server profile can be assigned and defined for each device bay so that the server blade can be powered
on and connected to a deployment network. These profiles can then later be modified or replaced by another
server profile.
A server profile can also be assigned to an empty bay to allow deployment at a later date.

Adding enet-network connections to a profile

To add a new Ethernet network connection to an existing server profile, use the add enet-connection

command:

>add enet-connection MyProfile network=MyNetwork pxe=enabled

To add a multiple network Ethernet connection on a server port, use the following commands:
>add enet-connection MyProfile pxe=enabled
>add server-port-map MyProfile:1 MyNetwork VlanID=100
If the domain setting for SharedServerVlanID is set to true, then the VlanID property cannot be

modified. Instead, the name of the shared uplink set with which the network is associated is required.
>add server-port-map MyProfile:1 MyNetwork Uplinkset=MyUplinkset

Adding iSCSI connections to a profile

To add a new iSCSI connection to an existing server profile, use the add iscsi-connection command:
add iscsi-connection MyProfile network=MyNetwork speedType=custom speed=2000
To configure the boot parameters for the iSCSI connection, use the set iscsi-boot-param command as

follows: