Interconnect – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 37

Advertising
background image

Command line 37

Item

Description

show igmp

Display Ethernet IGMP Snooping settings.

Syntax

show igmp

Example

->show igmp

Displays IGMP Snooping settings

interconnect

Manage I/O interconnect modules.
Supported actions: help, remove, show

Item

Description

remove interconnect

Remove an interconnect module from the domain. Normally this command is
used if a module has been physically removed from the enclosure. To be
removed, the module must not be currently in use by any element in the domain.

Syntax

remove interconnect <ModuleID|*>

Parameter

ModuleID(required)

The ID of the module to remove. The ID format is
<EnclosureID>:<BayNumber>. To display a list of the IDs corresponding to

modules in the domain, use the show interconnect command.

Examples

->remove interconnect enc0:2

Removes a specific interconnect module (bay 2) from the domain

->remove interconnect *

Removes all interconnect modules from the domain that are not present physically
in any enclosure

->remove interconnect enc0:*

Removes all interconnect modules that are not physically present in a specific

enclosure

->remove interconnect *:2

Removes interconnect modules (bay 2) from the domain that are not physically
present in all enclosures

Item

Description

show interconnect

Display all interconnect modules known to exist in the domain.

Syntax

show interconnect [<ModuleID>|*]

Parameter

ModuleID (optional)

The ID of the interconnect module. “*” displays detailed view of all the modules
in the VC domain. If not specified, a summary output of all the modules appears.

Examples

->show interconnect

Displays a summary listing of all interconnect modules

->show interconnect *

Displays detailed information for all interconnect modules

->show interconnect *:5

Displays detailed information for all enclosures with interconnect modules in