Setting options (secondary window), Changing the scp time (secondary window) – HP XP P9500 Storage User Manual

Page 124

Advertising
background image

B Performing Compatible FlashCopy operations (secondary

window)

This appendix describes how to perform Compatible FlashCopy operations using the previous
version of the Remote Web Console GUI, which opens in a secondary window.

Setting options (secondary window)

1.

Click Actions > Local Replications > BC Z/FC Z > Option.

2.

Click

to change to the Modify mode.

3.

In the Option window, select the check box for the option that you want to set.
If you want to remove an option, clear the check box in the Select Option(s) box.

4.

Click Apply.
The specified option is in effect.

Changing the SCP Time (secondary window)

1.

Click Actions > Local Replications > BC Z/FC Z > FC Z/FCSE.

2.

Click

to change to the Modify mode.

3.

In the Tree of the FC Z/FCSE window, select the LDKC that contains the CU that you want to
change the state-change-pending time.
The list of CUs displays on the right.

4.

Select and right-click the CU for which you want to change the state-change-pending time.
You may select multiple CUs at a time. If you select multiple CUs, the same state-change-pending
time will be applied to all selected CUs.

5.

In the menu, select the Set SCP Time command.
The Set SCP Time dialog box displays.

6.

Enter the state-change-pending time you want to set.

7.

Click OK.
The Set SCP Time dialog box closes and the changed state-change-pending time displays on
the FC Z/FCSE window.

8.

If you want to change the state-change-pending time of other CUs, repeat step 3 through
step 7.

9.

Click Apply.
The confirmation message displays and asks if it is OK to apply the changes of
state-change-pending time to the storage system.

10. Click OK.

The setting in the Set SCP Time dialog box applies to the storage system, and the
state-change-pending time changes.

CAUTION:

Remember that the state-change-pending time (SCP time) of Compatible FlashCopy

and Continuous Access Synchronous Z is the same. Therefore, when you are going to change the
state-change-pending time of Compatible FlashCopy, you need to decide the setting value,
considering that the state-change-pending time of Continuous Access Synchronous Z will be also
changed to the same value. For information about the state-change-pending time of Continuous
Access Synchronous Z, see the HP XP P9000 Continuous Access Synchronous for Mainframe
Systems User Guide
.

124

Performing Compatible FlashCopy operations (secondary window)

Advertising