Displaying information about pairs: flashcpy query – HP XP P9500 Storage User Manual

Page 69

Advertising
background image

Table 39 Information displayed by the FCQUERY command (continued)

Definition

Displayed
content

Displayed item

The relationship is established between the two Cnt Ac-S Z R-VOLs with the
Preserve Mirror FlashCopy function.

S

The relationship is in the status where the type of the Preserve Mirror FlashCopy
function (Preferred or Required) cannot be identified because the M-VOL and
R-VOL of Cnt Ac-S Z are mixed.

U

The number of tracks in the relationship.

-

NO. OF TRACKS

Displays the number of tracks that have not been copied.

-

TRACKS TO COPY

Using ICKDSF to view relationship states of Compatible FlashCopy

The following table shows the parameters you can use with the ICKDSF command.

Table 40 Parameters for the ICKDSF command

Description

Value

Parameter

Command

Sets the JCL statement identifying the volume. If the OS of the host
server is MVS, this parameter or the UNITADDRESS parameter is
required.

JCL statement

DDNAME or DNAME

FLASHCPY
QUERY

Sets the SYSNAME in the ASSGN system control statement. If the
OS of the host server is VSE, this parameter is required.

SYSNAME

SYSNAME

Specifies the device number (device address) of the S-VOL on which
you want to perform the FLASHCPY QUERY command. If the OS of

Source device
number

UNITADDRESS,
UNITADDR, or UNIT

the host server is MVS, this parameter or the DDNAME parameter
is required.

Specifies the CU number, the LDEV number, or the device number
of the S-VOL when you use the Remote FlashCopy function.

CU number

LDEV number

SOURCEVOL or
SRCVOL

Source device
number

Sets the JCL statement identifying the volume. If the OS of the host
server is MVS, this parameter or the UNITADDRESS parameter is
required.

JCL statement

DDNAME or DNAME

FLASHCPY
QUERY
RELATIONS

Sets the SYSNAME in the ASSGN system control statement. If the
OS of the host server is VSE, this parameter is required.

SYSNAME

SYSNAME

Specifies the device number (device address) of the S-VOL on which
you want to perform the FLASHCPY QUERY command. If the OS of

Source device
number

UNITADDRESS,
UNITADDR, or UNIT

the host server is MVS, this parameter or the DDNAME parameter
is required.

Displaying information about pairs: FLASHCPY QUERY

To display information about a Compatible FlashCopy pair, execute the ICKDSF FLASHCPY
QUERY

command. See the following example:

FLASHCPY QUERY UNIT(X'7000')

The following is an example of information displayed as a result of executing the FLASHCPY
QUERY

command:

FLASHCOPY VOLUME CAPABILITY INFORMATION TABLE
MAXIMUM
EXISTINO ALLOWED RELATIONS
RELATIONS EXCEEDED CAPABILITY
--------- --------- --------- ----------
1 1000 NO SRC CAP

Viewing relationship states of Compatible FlashCopy

69