The parameters that are available with the FLASHCOPY WITHDRAW command are shown in the
following table:
Table 51 Parameters for the FLASHCOPY WITHDRAW command
Description
Value
Parameter
Specifies the device number (device address or mini disk number),
the starting cylinder, and the ending cylinder of the copy source.
Primary device number, Starting
cylinder of source, Ending cylinder of
source
SOURCE
Specifies the device number (device address or mini disk number),
the starting cylinder, and the ending cylinder of the copy
destination. Up to 110 extents of copy target can be specified.
Secondary device number, Starting
cylinder of target, Ending cylinder of
target
TARGET
The relationship can be immediately cancelled even if the
background copy is not completed.
-
FORCE
Releasing Compatible FlashCopy relationships