HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 141

Advertising
background image

Virtual Connect fabrics 141

The VC-FC and FlexFabric modules use dynamic login distribution to equally distribute server logins

across all available uplink ports. The port with the least number of active logins is used for server

connectivity. When the number of logins is equal, VC-FC or FlexFabric modules utilize a round-robin
technique.

The VC-FC and FlexFabric modules use dynamic login distribution to provide an uplink port failover
path that enables server connections to fail over within the VC SAN fabric. If a VC SAN fabric uplink

port becomes unavailable, servers logged in through that uplink are automatically reconnected using

one of the remaining uplinks in the VC SAN fabric, resulting in automatic failover.

When a previously failed uplink is reconnected to the fabric, no server logins on the VC-FC modules are
moved to the newly available port. This can cause an unbalanced situation where some uplink ports

have more server logins than others. When enabled for VC FlexFabric modules, Automatic Login

Advertising