Login re-distribution – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 149

Advertising
background image

Virtual Connect fabrics 149

Task

Description

Set the preferred or maximum FCoE

connection speed

After a FlexFabric module port has been added, select the Show

Advanced Settings checkbox, click the selection box, and then select a

setting (0.1Gb to 8 Gb):

Set Preferred FCoE Connection Speed—Applies to server profiles

with an FCoE connection specified. Select a speed value for the

FCoE connection and server port associated with this fabric.

Set Maximum FCoE Connection Speed—Applies to server profiles
with an FCoE connection specified. This setting limits the maximum

port speed from the server for the FCoE connection associated with

this fabric.

Delete an uplink port

Left-click an uplink port row to select it, right-click to display a menu, and
then select Delete Port, or click Delete in the Action column.

Save changes

Click Apply.

Cancel without saving changes

Click Cancel.

Login re-distribution

Login Re-Distribution
When creating or editing a SAN fabric using HP VC FlexFabric 10Gb/24-port Modules in a FabricAttach

fabric, select the Show Advanced Settings checkbox to select the login re-distribution:

Manual Login Re-Distribution—Default for all FC modules. You must initiate a Login Re-Distribution

request through the VC GUI or CLI interfaces. You might re-distribute logins if an uplink that was
previously down is now available, if you added an uplink to a fabric, or if the number of logins through

each available uplink has become unbalanced for any reason.

Automatic Login Re-Distribution—When selected, the VC FlexFabric module initiates Login
Re-Distribution automatically when the specified time interval expires. For more information about

setting the time interval, see "Fibre Channel Settings (Misc.) screen (on page

156

)" .

The automatic option is only available on FlexFabric modules in a FabricAttach fabric and enables you to

specify an interval, in seconds, for the length of time the previously offline links must be stable before the
module can re-distribute logins. Login re-distribution is not supported for DirectAttach fabrics.
FCoE Connection Speed
To change these settings, click the selection box, and then select a setting (100Mb to 8Gb):

Set a custom value for the Preferred FCoE Connection Speed. This value is the default speed for server
profile connections mapped to this network. The server administrator can override this setting on an

individual profile connection.

Advertising