Virtual Connect domains 39

Modules not redundantly connected, failure of module enc0:iobay1 or

enc0:iobay2 or enc1:iobay2 will isolate some modules; Port enc0:iobay5:d3:v1

loop detected and automatically disabled

The domain managed status ReasonCodes are provided in the following table.

Domain reason code

Description

vcDomainOk

All enclosures and profiles are normal in the domain.

vcDomainAbnormalEnclosuresAndProfil

es

One or more enclosures and profiles are abnormal in the domain.

vcDomainSomeEnclosuresAbnormal

At least one enclosure is not OK or Degraded.

vcDomainUnmappedProfileConnections The profile contains connections that are not mapped to a server port.
vcDomainStackingFailed

All stacking links between one or more modules have failed.

vcDomainStackingNotRedundant

Some stacking links between one or more modules have failed, but

connectivity still exists between modules.

vcDomainSomeProfilesAbnormal

One or more profiles in the domain are abnormal.

vcDomainUnknown

The condition of the domain cannot be determined.

vcDomainOverProvisioned

More than 16 VC modules are in the domain.

vcEnclosureManagedStatusChanged
The following is an example of an enclosure Cause string:

2 of 6 Ethernet modules are abnormal in enclosure enc0

The following is an example of an enclosure RootCause string:

Module in bay enc0:iobay3 has been removed

The enclosure managed status ReasonCodes are provided in the following table.

Enclosure reason code

Description

vcEnclosureOk

The enclosure is normal.

vcEnclosureAllEnetModulesFailed

All Ethernet modules are abnormal, none are OK or degraded.

vcEnclosureSomeEnetModulesAbnormal One or more Ethernet modules are abnormal.
vcEnclosureSomeModulesOrServersInco

mpatible

The enclosure contains incompatible modules, or configured modules

are missing.

vcEnclosureSomeFcModulesAbnormal

One or more FC modules are abnormal.

vcEnclosureSomeServersAbnormal

At least one server is in a known state and no servers are OK, or at
least one server is degraded.

vcEnclosureUnknown

The condition of the enclosure cannot be determined, or the state of

servers or modules is unknown.

vcModuleManagedStatusChanged
The following is an example of a module Cause string:

Port enc0:iobay5:d3:v1 loop detected and automatically disabled

The following is an example of a module RootCause string:

Port enc0:iobay5:d3:v1 loop detected and automatically disabled

The module managed status ReasonCodes are provided in the following table.

Module reason code

Description

vcEnetmoduleOk

The Ethernet module is functioning normally.