HP ESL E-series Tape Libraries User Manual

Page 115

Advertising
background image

Sense

key

ASC

ASCQ Message name / description

4

84

See

Table

22

VERTICAL HARDWARE FAILURE

•

Remove any obstructions.

•

Run the Robotics Self Test from the OCP.

4

85

See

Table

22

HORIZONTAL HARDWARE FAILURE

•

Remove any obstructions.

•

Run the Robotics Self Test from the OCP.

4

87

See

Table

22

DEPTH HARDWARE FAILURE

•

Remove any obstructions.

•

Run the Robotics Self Test from the OCP.

4

88

00

WARNING SAFE TEMPERATURE EXCEEDED
This is a warning that the temperature in the library exceeds the normal

operational temperature 40

o

C (104

o

F).

4

88

01

MAXIMUM TEMPERATURE EXCEEDED
The robot in the overheated cabinet turns off and remains off until the

temperature returns to an acceptable level. For LTO, the acceptable level

is 52

o

C (127

o

F); for SDLT, the acceptable level is 49

o

C (120

o

F).

•

Check whether the air filters need to be replaced.

•

Check for fan failure.

•

Lower the ambient temperature.

4

89

00–FF

VISION HARDWARE FAILURE
Vision internal failure.

4

8A

02

CALIBRATION FAILURE
Check slots, cartridges, targets, and all internal elements. Verify that the

panels are properly seated and that doors are closed.

4

8B

See

Table

22

CLM HARDWARE FAILURE
CLM failure.

4

8C

06

LOAD PORT DOOR OPEN
Load port door unlocked but failed to open.

4

8E

02

SCSI UPGRADE TRANSFER FAILED
A data transfer error or a data storage error was received during the

firmware upgrade.

4

8E

03

CABINET CONTROLLER UNABLE TO UPLOAD
Unable to upload firmware to the cabinet controller.

•

Retry the download.

•

Check cable connections.

•

Replace Smart Media and retry.

4

8E

04

ROBOTICS CONTROLLER UNABLE TO UPLOAD
Unable to upload firmware to the robotic controller. Verify that the

firmware image is correct and attempt to update again.

4

F2

00

I2C BUS COMMUNICATION FAILURE
Unable to communicate with the drive cluster.

•

Check I2C cable connection on the drive cluster.

•

Check that the cluster is powered on.

•

Check the LED status of the cluster controller.

HP StorageWorks

115