Diagnostics screen, 45 operations screen (secondary cabinet), 11 diagnostic tests – HP ESL E-series Tape Libraries User Manual

Page 67

Advertising
background image

10650

Figure 45 Operations screen (secondary cabinet)

To view or manage the operations information, use the Up and Down buttons to highlight the section

and press Select.

To toggle the cabinet between online and offline, use the Up and Down arrows to highlight

Cabinet, then press Select. Use the Up and Down arrows to choose Online or Offline, then

press Select.

To view the CLM firmware revision number, use the Up and Down arrows to highlight CLM,

then press Select. Use the Up and Down arrows to select Details, then press Select again. The

firmware revision is displayed.

To display details of each drive, use the Up and Down arrows to highlight Drive #, then press

Select. Use the Up and Down arrows to select Details, then press Select again. Drive details

are displayed.

Diagnostics screen

The Diagnostics screen allows you to perform the following diagnostic tests on the library (see

Table 11

).

NOTE:

The library must be off-line to run diagnostic testing.

Table 11 Diagnostic tests

Test

Description

Robotics Self Test

Checks for unrestricted motion of the library robotics.

Individual Axis Self Test

Allows testing repeated motions of each axis for service

debug and verification purposes. When setting up the test

on a CLM library, specify the CLM axis to test.

Robotics to Home Position

Calibrates the library robotics and sets it to the bottom of

the library with the optical sensor facing the back.

Calibrate Cabinet

Checks the position of all panels and columns, checks that

the picker is aligned with the slots.

Read Cabinet Serial Number

Verifies that the serial number barcode can be read, then

displays the serial number of the cabinet.

Read Cabinet IEEE Id

Verifies that the IEEE Id barcode can be read, then

displays the IEEE Id of the cabinet.

HP StorageWorks

67

Advertising